T-GARC Node: Datasets for Technology Database for Carbon Neutrality
Data stock: Default root data stock [ Download ]

Process data set overview page

Data set: carbon dioxide, captured; wet solvent capture route, from coal-fired power plant flue gas, CCUS; single route, design based, at plant; >= 95 mol% CO2 (wet) (00.00.015)

A more recent version of this data set exists in the database.

Most recent version of this data set:00.00.017

Full name
carbon dioxide, captured; wet solvent capture route, from coal-fired power plant flue gas, CCUS; single route, design based, at plant; >= 95 mol% CO2 (wet)
Location
KR
Reference year
2024
Valid until
2030
Reference flow(s)
Type
LCI result
Parameterized?
no
LCIA results included?
yes
Category
Materials production / Inorganic chemicals
Synonyms
Use advice for data set
The dataset contains a negative fossil CO2 emission (emission reduction at the power plant allocated to the captured CO2); do not combine it with the emissions of the same power plant (double counting). The captured CO2 is of fossil origin; its release when the product is used or at end of life must be accounted for by the user. CO2 compression, liquefaction, transport and storage are not included.
Data set use approval
General comment
This dataset is part of a set of LCI datasets for CCUS (carbon capture, utilisation and storage) technologies developed in Korea. This dataset represents 1 kg of CO2 captured from the flue gas of a Korean coal-fired power plant by post-combustion capture with an aqueous amine solvent, modelled as a CO2 feedstock. The power plant with capture supplies two functions, electricity and captured CO2. Following an underlying physical relationship, the changes caused by capture (additional hard coal to compensate the energy penalty and the reduced CO2 emission) are allocated to the captured CO2; the dataset therefore contains a negative fossil CO2 emission. Capture rate about 90%; CO2 purity at least 95 mol% (wet). CO2 compression, liquefaction, transport and storage are not included. The capture data are based on a feasibility study of a 3,000 t/d capture plant (MEA solvent) and on design and operating data of a 10 t/d pilot plant at the Taean coal-fired power plant (MAB solvent).
LCI Method Principle
Other
LCI Method Approaches
No records found.
Completeness of product model
All relevant flows quantified
Reviews
  • Independent external review by
    Data quality indicators
    • Overall quality: Very good - 1.8
    • Methodological appropriateness and consistency: Good
    • Precision: Good - 2.0
    • Completeness: Fair
    • Geographical representativeness: Very good - 1.0
    • Time representativeness: Good - 2.0
    • Technological representativeness: Good - 2.0
License and access conditions
Copyright
yes
Owner of data set
T-GARC
Technical purpose
Intended for use in life cycle assessment studies for the development of carbon reduction technologies.
Input Products
No records found.
Co-Products
No records found.
Data set version
00.00.015
Time stamp (last saved)
2026-10-15T22:26:51.906+09:00
Data set format
Other versions
Compliance systems
  • Commission Recommendation (EU) 2021/2279. (Annex II - Part A. Requirements to develop PEFCRs and perform PEF studies in compliance with an existing Product Environmental Footprint Category Rule) (Overall compliance: Not compliant)
  • Environmental Footprint 3.1 (Overall compliance: Not compliant)
  • ILCD Data Network - Entry-level (Overall compliance: Fully compliant)
  • ISO 14040 Environmental Management – Life Cycle Assessment – Principles and Framework, 2006 (Overall compliance: Fully compliant)
  • ISO 14044:2006. Environmental Management – Life Cycle Assessment – Requirements and guidelines. (Overall compliance: Fully compliant)